Contact USA Rep Organizations In Your AreaSee List on the Contact US tab
Contact USA Inside SalesCatherine Topar
Ph: 203-334-7537
Fx: 203-334-7792
Email: ctopar@e-jpc.com
Product NavigatorSearch By Specification Search By Keyword
Shop
Elinco's VH series BLDC motors are an ideal choice for application that requires high reliability, high efficiency, and high power to volume ratio. They are capable of providing a large amount of torque over different speed ranges. The VH series motors are internally commutated motors designed to run from direct current source.
Unit of Measure

Series

N/A VH Inner Rotor

Motor Frame Size

N/A 86 x 125 mm

Number of Poles

N/A 8

Rated Voltage

N/A 48 V

Rated Torque

N/A 2200 mN·m

Rated Speed

N/A 3000 rpm

Rotor Inertia

N/A 2400 g·cm²

Insulation Class

N/A Class B

Rated Torque

N/A 2.2 N·m

Rated Power

N/A 700 W

Peak Torque

N/A 6.66 N·m

Line to Line Inductance

N/A 0.24 mH

Winding Type

N/A Star

Hall Effect Electrical Angle

N/A 120 º

Shaft Runout

N/A 0.05 mm

Radial Play at 450 Gram (g) Load

N/A 0.02 mm

End Play at 4000 Gram (g) Load

N/A 0.08 mm

Maximum Radial Force at 20 Millimeter (mm) from the Flange

N/A 220 N

Maximum Axial Force

N/A 45 N

Minimum Insulation Resistance for 500 Volt (V) Direct Current (DC) Voltage

N/A 100 MO

Number of Phase

N/A 3

Peak Current

N/A 52 A

Body Length

N/A 125 mm

Line to Line Resistance at 20 Degree Celsius (ºC) Temperature

N/A 0.1 O

Back Electromotive Force (EMF) Constant

N/A 9.7 Vrms/Krpm

Direct Current (DC) Dielectric Strength Voltage for One Minute

N/A 500 V

Lead Number

N/A 1 2 3 4 5 6 7 8

Color for Lead Number 1

N/A Red

Color for Lead Number 2

N/A Blue

Color for Lead Number 3

N/A Green

Color for Lead Number 4

N/A White

Color for Lead Number 5

N/A Black

Color for Lead Number 6

N/A Yellow

Color for Lead Number 7

N/A Red

Color for Lead Number 8

N/A Black

Lead Gauge for Lead Number 1

N/A American Wire Gauge (AWG) 26 Underwriters Laboratories (UL) 1332

Lead Gauge for Lead Number 2

N/A American Wire Gauge (AWG) 26 Underwriters Laboratories (UL) 1332

Lead Gauge for Lead Number 3

N/A American Wire Gauge (AWG) 26 Underwriters Laboratories (UL) 1332

Lead Gauge for Lead Number 4

N/A American Wire Gauge (AWG) 26 Underwriters Laboratories (UL) 1332

Lead Gauge for Lead Number 5

N/A American Wire Gauge (AWG) 26 Underwriters Laboratories (UL) 1332

Lead Gauge for Lead Number 6

N/A American Wire Gauge (AWG) 14 Underwriters Laboratories (UL) 1332

Lead Gauge for Lead Number 7

N/A American Wire Gauge (AWG) 14 Underwriters Laboratories (UL) 1332

Lead Gauge for Lead Number 8

N/A American Wire Gauge (AWG) 14 Underwriters Laboratories (UL) 1332

Electric Function for Lead Number 1

N/A Voltage Collector Collector (Vcc) (Power Supply Positive for Hall)

Electric Function for Lead Number 2

N/A Hall A

Electric Function for Lead Number 3

N/A Hall B

Electric Function for Lead Number 4

N/A Hall C

Electric Function for Lead Number 5 (Hall Negative)

N/A GND (Power Supply Negative of Hall)

Electric Function for Lead Number 6

N/A Phase U

Electric Function for Lead Number 7

N/A Phase V

Electric Function for Lead Number 8

N/A Phase W

Voltage for Lead Number 1

N/A +5 to +24


VH86S125700-48