Contact USA Rep Organizations In Your AreaSee List on the Contact US tab
Contact USA Inside SalesCatherine Topar
Ph: 203-334-7537
Fx: 203-334-7792
Email: ctopar@e-jpc.com
Product NavigatorSearch By Specification Search By Keyword
Shop
Elinco's VH series BLDC motors are an ideal choice for application that requires high reliability, high efficiency, and high power to volume ratio. They are capable of providing a large amount of torque over different speed ranges. The VH series motors are internally commutated motors designed to run from direct current source.
Unit of Measure

Series

VH Inner Rotor

Motor Frame Size

57 x 76 mm

Number of Poles

8

Rated Voltage

36 V

Rated Torque

300 mN·m

Rated Speed

3000 rpm

Rotor Inertia

210 g·cm²

Insulation Class

Class B

Rated Torque

0.3 N·m

Rated Power

94 W

Peak Torque

0.9 N·m

Line to Line Inductance

1.2 mH

Winding Type

Star

Hall Effect Electrical Angle

120 º

Shaft Runout

0.025 mm

Radial Play at 460 Gram (g) Load

0.025 mm

Maximum Radial Force at 20 Millimeter (mm) from the Flange

115 N

Maximum Axial Force

45 N

Minimum Insulation Resistance for 500 Volt (V) Direct Current (DC) Voltage

100 MO

Number of Phase

3

Peak Current

12.3 A

Torque Constant

0.124 N·m/A

Body Length

76 mm

Tolerance (±) for Rated Speed

10 %

Line to Line Resistance at 20 Degree Celsius (ºC) Temperature

1.2 O

Tolerance (±) for Line to Line Inductance

20 %

Back Electromotive Force (EMF) Constant

5.6 Vrms/Krpm

Direct Current (DC) Dielectric Strength Voltage for One Minute

500 V

Lead Number

1 2 3 4 5 6 7 8

Color for Lead Number 1

Red

Color for Lead Number 2

Yellow

Color for Lead Number 3

Blue

Color for Lead Number 4

Purple

Color for Lead Number 5

Black

Color for Lead Number 6

Red

Color for Lead Number 7

Blue

Color for Lead Number 8

Black

Lead Gauge for Lead Number 1

American Wire Gauge (AWG) 28 Underwriters Laboratories (UL) 3265

Lead Gauge for Lead Number 2

American Wire Gauge (AWG) 28 Underwriters Laboratories (UL) 3265

Lead Gauge for Lead Number 3

American Wire Gauge (AWG) 28 Underwriters Laboratories (UL) 3265

Lead Gauge for Lead Number 4

American Wire Gauge (AWG) 28 Underwriters Laboratories (UL) 3265

Lead Gauge for Lead Number 5

American Wire Gauge (AWG) 28 Underwriters Laboratories (UL) 3265

Lead Gauge for Lead Number 6

American Wire Gauge (AWG) 18 Underwriters Laboratories (UL) 1430

Lead Gauge for Lead Number 7

American Wire Gauge (AWG) 18 Underwriters Laboratories (UL) 1430

Lead Gauge for Lead Number 8

American Wire Gauge (AWG) 18 Underwriters Laboratories (UL) 1430

Electric Function for Lead Number 1

Voltage Collector Collector (Vcc) (Power Supply Positive for Hall)

Electric Function for Lead Number 2

Hall A

Electric Function for Lead Number 3

Hall B

Electric Function for Lead Number 4

Hall C

Electric Function for Lead Number 5 (Hall Negative)

GND (Power Supply Negative of Hall)

Electric Function for Lead Number 6

Phase U

Electric Function for Lead Number 7

Phase V

Electric Function for Lead Number 8

Phase W

Voltage for Lead Number 1

+5 to +24

Tolerance for Torque Constant (±)

10 %

Tolerance for Back Electromotive Force (EMF) Constant (±)

10 %