Elinco's VH series BLDC motors are an ideal choice for application that requires high reliability, high efficiency, and high power to volume ratio. They are capable of providing a large amount of torque over different speed ranges. The VH series motors are internally commutated motors designed to run from direct current source.
Unit of Measure
Series |
N/A VH Inner Rotor |
Motor Frame Size |
N/A 22 x 45 mm |
Number of Poles |
N/A 8 |
Rated Voltage |
N/A 24 V |
Rated Torque |
N/A 8 mN·m |
Rated Speed |
N/A 4600 rpm |
Rotor Inertia |
N/A 0.66 g·cm² |
Insulation Class |
N/A Class B |
Weight |
N/A 0.07 kg |
Rated Torque |
N/A 8 mN·m |
Rated Power |
N/A 4 W |
Peak Torque |
N/A 21 mN·m |
Line to Line Resistance |
N/A 23 ohms |
Line to Line Inductance |
N/A 6 mH |
Winding Type |
N/A Star |
Hall Effect Electrical Angle |
N/A 120 º |
Shaft Runout |
N/A 0.025 mm |
Radial Play at 450 Gram (g) Load |
N/A 0.02 mm |
End Play at 450 Gram (g) Load |
N/A 0.08 mm |
Maximum Axial Force |
N/A 2 N |
Minimum Insulation Resistance for 500 Volt (V) Direct Current (DC) Voltage |
N/A 100 MO |
Number of Phase |
N/A 3 |
Continuous Stall Torque |
N/A 10 mN·m |
Peak Current |
N/A 1 A |
Torque Constant |
N/A 30 mN·m/A |
Body Length |
N/A 45 mm |
Maximum Radial Force at 10 Millimeter (mm) from The Flange |
N/A 10 N |
Back Electromotive Force (EMF) Constant |
N/A 2 Vrms/Krpm |
Direct Current (DC) Dielectric Strength Voltage for One Minute |
N/A 500 V |
Lead Number |
N/A 1 2 3 4 5 6 7 8 |
Color for Lead Number 1 |
N/A Blue |
Color for Lead Number 2 |
N/A Red |
Color for Lead Number 3 |
N/A Yellow |
Color for Lead Number 4 |
N/A Brown |
Color for Lead Number 5 |
N/A Green |
Color for Lead Number 6 |
N/A Red |
Color for Lead Number 7 |
N/A Brown |
Color for Lead Number 8 |
N/A Black |
Lead Gauge for Lead Number 1 |
N/A American Wire Gauge (AWG) 28 Underwriters Laboratories (UL) 1007 |
Lead Gauge for Lead Number 2 |
N/A American Wire Gauge (AWG) 28 Underwriters Laboratories (UL) 1007 |
Lead Gauge for Lead Number 3 |
N/A American Wire Gauge (AWG) 28 Underwriters Laboratories (UL) 1007 |
Lead Gauge for Lead Number 4 |
N/A American Wire Gauge (AWG) 28 Underwriters Laboratories (UL) 1007 |
Lead Gauge for Lead Number 5 |
N/A American Wire Gauge (AWG) 28 Underwriters Laboratories (UL) 1007 |
Lead Gauge for Lead Number 6 |
N/A American Wire Gauge (AWG) 26 Underwriters Laboratories (UL) 1007 |
Lead Gauge for Lead Number 7 |
N/A American Wire Gauge (AWG) 26 Underwriters Laboratories (UL) 1007 |
Lead Gauge for Lead Number 8 |
N/A American Wire Gauge (AWG) 26 Underwriters Laboratories (UL) 1007 |
Electric Function for Lead Number 1 |
N/A Voltage Collector Collector (Vcc) (Supply Voltage for Hall) |
Electric Function for Lead Number 2 |
N/A Hall A |
Electric Function for Lead Number 3 |
N/A Hall B |
Electric Function for Lead Number 4 |
N/A Hall C |
Electric Function for Lead Number 5 (Hall Negative) |
N/A GND (Power Supply Negative of Hall) |
Electric Function for Lead Number 6 |
N/A Phase U |
Electric Function for Lead Number 7 |
N/A Phase V |
Electric Function for Lead Number 8 |
N/A Phase W |
Voltage for Lead Number 1 |
N/A +5 to +24 |
|
|
N/A Custom Designs |