Item # |
Item Name |
Series |
Dimensions |
Rated Voltage |
Max Airflow |
Max Static Pressure |
Request Quote |
---|---|---|---|---|---|---|---|
E2271Z24B5YP-00 | N/A 470 Pascal (Pa) Maximum Static Pressure Super Silent Blower with Sensor | Series N/A DC Centrifugal Blowers | Dimensions N/A ø 220 x 71 mmø 8.7 x 2.8 in | Rated Voltage N/A 24 V | Max Airflow N/A 519 cfm14.7 m³/min | Max Static Pressure N/A 470 Pa1.89 inH2O | Request Quote |
E2271Z48B7AP-00 | N/A 650 Pascal (Pa) Maximum Static Pressure Super Silent Blower with Sensor | Series N/A DC Centrifugal Blowers | Dimensions N/A ø 220 x 71 mmø 8.7 x 2.8 in | Rated Voltage N/A 48 V | Max Airflow N/A 639 cfm18.1 m³/min | Max Static Pressure N/A 650 Pa2.61 inH2O | Request Quote |
E1033H12B5AM-04 | N/A 120 Pascal (Pa) Maximum Static Pressure Super Silent Blower with Sensor | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 12 V | Max Airflow N/A 19 cfm0.53 m³/min | Max Static Pressure N/A 120 Pa0.48 inH2O | Request Quote |
E1033H12B6AM-04 | N/A 185 Pascal (Pa) Maximum Static Pressure Super Silent Blower with Sensor | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 12 V | Max Airflow N/A 23 cfm0.64 m³/min | Max Static Pressure N/A 185 Pa0.74 inH2O | Request Quote |
E1033H12B7AZ-00 | N/A 260 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 12 V | Max Airflow N/A 27 cfm0.76 m³/min | Max Static Pressure N/A 260 Pa1.05 inH2O | Request Quote |
E1033H12B8AZ-00 | N/A 320 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 12 V | Max Airflow N/A 30 cfm0.85 m³/min | Max Static Pressure N/A 320 Pa1.29 inH2O | Request Quote |
E1033H12BAAZ-00 | N/A 500 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 12 V | Max Airflow N/A 40 cfm1.14 m³/min | Max Static Pressure N/A 500 Pa2.01 inH2O | Request Quote |
E1033H24B5AM-04 | N/A 120 Pascal (Pa) Maximum Static Pressure Super Silent Blower with Sensor | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 24 V | Max Airflow N/A 19 cfm0.53 m³/min | Max Static Pressure N/A 120 Pa0.48 inH2O | Request Quote |
E1033H24B6AZ-00 | N/A 185 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 24 V | Max Airflow N/A 23 cfm0.64 m³/min | Max Static Pressure N/A 185 Pa0.74 inH2O | Request Quote |
E1033H24B7AZ-00 | N/A 260 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 24 V | Max Airflow N/A 27 cfm0.76 m³/min | Max Static Pressure N/A 260 Pa1.05 inH2O | Request Quote |
E1033H24B8AZ-00 | N/A 320 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 24 V | Max Airflow N/A 30 cfm0.85 m³/min | Max Static Pressure N/A 320 Pa1.29 inH2O | Request Quote |
E1033H24BAAZ-00 | N/A 500 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 24 V | Max Airflow N/A 40 cfm1.14 m³/min | Max Static Pressure N/A 500 Pa2.01 inH2O | Request Quote |
E1033L12BBAZ-00 | N/A 700 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 12 V | Max Airflow N/A 40.6 cfm1.15 m³/min | Max Static Pressure N/A 700 Pa2.81 inH2O | Request Quote |
E1033L12BCAZ-00 | N/A 840 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 12 V | Max Airflow N/A 44 cfm1.25 m³/min | Max Static Pressure N/A 840 Pa3.36 inH2O | Request Quote |
E1033L24BBAZ-00 | N/A 700 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 24 V | Max Airflow N/A 40.6 cfm1.15 m³/min | Max Static Pressure N/A 700 Pa2.81 inH2O | Request Quote |
E1033L24BCAZ-00 | N/A 840 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 33 mm3.8 x 3.7 x 1.3 in | Rated Voltage N/A 24 V | Max Airflow N/A 44 cfm1.25 m³/min | Max Static Pressure N/A 840 Pa3.36 inH2O | Request Quote |
E1027H12B7AZ-00 | N/A 315 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 25 mm3.8 x 3.7 x 1.0 in | Rated Voltage N/A 12 V | Max Airflow N/A 20 cfm0.57 m³/min | Max Static Pressure N/A 315 Pa1.27 inH2O | Request Quote |
E1027H12BAAZ-00 | N/A 520 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 97 x 95 x 25 mm3.8 x 3.7 x 1.0 in | Rated Voltage N/A 12 V | Max Airflow N/A 28 cfm0.78 m³/min | Max Static Pressure N/A 520 Pa2.09 inH2O | Request Quote |
SFBD12B4 | N/A 120 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 94 x 30 mm3.7 x 1.2 in | Rated Voltage N/A 12 V | Max Airflow N/A 16 cfm0.44 m³/min | Max Static Pressure N/A 120 Pa0.48 inH2O | Request Quote |
SFBD12H7 | N/A 280 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 94 x 30 mm3.7 x 1.2 in | Rated Voltage N/A 12 V | Max Airflow N/A 23 cfm0.65 m³/min | Max Static Pressure N/A 280 Pa1.13 inH2O | Request Quote |
SFBD12Z7 | N/A 200 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 94 x 30 mm3.7 x 1.2 in | Rated Voltage N/A 12 V | Max Airflow N/A 20 cfm0.56 m³/min | Max Static Pressure N/A 200 Pa0.8 inH2O | Request Quote |
SFBD24B4 | N/A 120 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 94 x 30 mm3.7 x 1.2 in | Rated Voltage N/A 24 V | Max Airflow N/A 16 cfm0.44 m³/min | Max Static Pressure N/A 120 Pa0.48 inH2O | Request Quote |
SFBD24H7 | N/A 280 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 94 x 30 mm3.7 x 1.2 in | Rated Voltage N/A 24 V | Max Airflow N/A 23 cfm0.65 m³/min | Max Static Pressure N/A 280 Pa1.13 inH2O | Request Quote |
SFBD24Z7 | N/A 200 Pascal (Pa) Maximum Static Pressure Super Silent Blower | Series N/A DC Centrifugal Blowers | Dimensions N/A 94 x 30 mm3.7 x 1.2 in | Rated Voltage N/A 24 V | Max Airflow N/A 20 cfm0.56 m³/min | Max Static Pressure N/A 200 Pa0.8 inH2O | Request Quote |
G0938B12B8ZP-00 | N/A DC Axial Fan Fixed Blade Type | Series N/A High Pressure Fans | Dimensions N/A 92 x 38 mm3.62 x 1.5 in | Rated Voltage N/A | Max Airflow N/A 113 cfm3.2 m³/min | Max Static Pressure N/A 350 Pa1.41 inH2O | Request Quote |