- Motors are designed small and high performance
- We recently released a special magnetic circuit design motor. This motor design is smaller and has a higher performance than conventional FED, FYD series motors.
- Wide range (200 r/min-2500 r/min 60 W:65 r/min-2500 r/min), stepless speed control.
- Very steady characteristics (Feed back control employed).
- Speed pulse output can be used for speed monitoring, simplified position control...
- Direction of rotation can be monitored by this signal.
- At an over-load condition, the motor stops and an alarm signal is output.
| Type | N/A Palm Mini Plus J-Book Type Motors 61X61 | 
| Product Type | N/A DC Motor | 
| Series | N/A FHD | 
| Motor Frame Size | N/A 61 x 61 mm2.4 x 2.4 in | 
| Number of Poles | N/A 14 | 
| Shaft Specification | N/A Pinion Shaft Type | 
| Rated Voltage | N/A 24 V | 
| Rated Voltage | N/A 24 V | 
| Rated Output | N/A 20 W | 
| Rated Torque | N/A 98 mN·m14 oz·in | 
| Rated Speed | N/A 2000 r/min | 
| Speed Control Range | N/A 200 to 2500 r/min | 
| Max. Instantaneous Torque (in 5 sec.) | N/A 150 mN·m (2000 r/min) 21 oz·in (2000 r/min) | 
| Speed Setting Method | N/A (1) Speed setting by external speed setter (Sold separately: model code Q-R10KB) (2) Speed setting by external voltage supply 0~10V | 
| Speed Setting | N/A 300±5 % | 
| Speed Variation (Against Load ±1%) | N/A 0~rated torque at rated voltage and speed | 
| Speed Variation (Against Voltage ±1%) | N/A Rated voltage ± 10 % at rated speed, no load | 
| Input Signal | N/A H : Open collector L : GND (0~0.8V) Run, Brake, F/R IN, Alarm RST (Only 60W) | 
| Output Signal | N/A 10 mA. Max. Alarm, Speed Out (Pulse Output), F/R Out Open Collector Output DC 30 V Max. | 
| Speed Pulse (Pulse/Revolution) | N/A 42 | 
| Max. Average Current Rated | N/A 1.8 A | 
| Max. Peak Current Rated | N/A 9 A | 
| Operation Temperature | N/A 0~40ºC (no condensation) continuous duty. The motor flange surface temp. must be 80ºC Max. (Ambient temperature 40ºC without heat sink) | 
| Motor Dielectric Strength | N/A Withstand for 1 min. under AC500V 50Hz (Between case and coil) | 
| Motor Insulation Resistance | N/A 10 MO MIN. (20 W, 40 W) 100 MO; MIN. (60 W) (Between case and coil by DC 500 V tester) | 
| Note | N/A Minimum Order Quantity May Apply | 
| Max. Instantaneous Torque at 2000 r/min (in 5 sec.) | N/A 150 mN·m21 oz·in | 
| Speed Variation (Against Temperature ±3%) | N/A 20 ±20ºC at rated voltage and speed, no load | 
| Protection Functions | N/A
                                                                                        Over load protection When an exceeding torque than rated is applied to motor for more than about 5 sec., Stop motor and outputs "L" from "ALARM" (20W, 40W) or "ALARM OUT" (60W). To release alarm : Palm Mini PLUS type: Disconnect power supply for more than 1min J-Book type: Input "L" to "ALARM RST" for more than 1sec. Do not measure/judge by this operation whether the motor is overloaded or not. | 
| Rated Power | N/A 20 W | 
| Peak Current | N/A 9 A | 
| 
                                                                             | 
| 
                                                                             | 
| 
                                                                             | 
| N/A Custom Designs | 

 
   
   
         
        