Print Back
This is a kind of capacitor-run, single-phase induction motor which has characteristics somewhat different from those of induction motor and reversible motor.

When driven at 115V, the duty time is 5 minutes, but, at 70V, the duty is continuous and the motor does not overheat even if the output shaft is locked from outside.

Further, by changing voltage, motor speed and torque change simultaneously, the motor can be kept in continuous running, therefore, at a desirable voltage and torque (at below 70V).

Because this motor puts forth its maximum torque at starting as mentioned above, start, stop and rotation reversing can be done without difficulty.
Unit of Measure

Specifications

Product Type

N/A Torque Motor

Motor Type

N/A Torque Motor

Speed Control

N/A With Speed Control

Series

N/A UTH

Motor Frame Size

N/A 3.15 x 3.15 in

Rated Output

N/A 12 W

Shaft Specification

N/A Pinion Shaft Motor

No. of Poles

N/A 4

Speed at Max. Output

N/A 900 rpm

Starting Torque

N/A 28 oz·in2000 g·cm

Starting Current

N/A 0.85 A

Input at Start

N/A 85 W

No Load Speed

N/A 1500 rpm

Time Rating

N/A 5 Minutes

Capacitor

N/A 7.0 µF

Voltage

N/A 115 V

Frequency

N/A 60 Hz

Phase

N/A Single

Duty Cycle

N/A 5 Minutes

Insulation

N/A Class A

Torque Curve


a1450.jpg

Dimensions


Pinion Shaft Motor

Additional Information


Dynamic Characteristics

Motor Selection Guide

Motor/Gearhead Model Coding

Motor-Size Chart

UTH Series Synchronous Motor

Customize

N/A Custom Designs