Type |
N/A Simple Type Motors |
Product Type |
N/A DC Motor |
Series |
N/A FYD |
Motor Frame Size |
N/A 61 x 61 mm2.4 x 2.4 in |
Shaft Specification |
N/A Pinion Shaft |
Rated Speed |
N/A 1500 r/min |
Speed Control Range |
N/A 200 to 2500 r/min |
Rated Voltage |
N/A 24 V |
Rated Output |
N/A 6 W |
Speed Setting Method |
N/A (1) Speed setting by external speed setter (Sold separately: model code Q-R10KB) (2) Speed setting by external voltage supply 0~10V |
Speed Setting |
N/A 300±5 % |
Speed Variation (Against Load ±1%) |
N/A 0~rated torque at rated voltage and speed |
Speed Variation (Against Voltage ±1%) |
N/A DC 24 V ± 10 % at rated speed, no load |
Speed Variation (Against Temperature ±1%) |
N/A 20 ± 20ºC at rated voltage and speed, no load |
Input Signal |
N/A H : Open collector L : GND (0~0.8V) Run, Brake, F/R IN |
Output Signal |
N/A Alarm Out, HU Out, HV Out Open Collector Output DC 30 V Max. 10 MA Max. |
Speed Pulse (Pulse/Revolution) |
N/A 5 |
Max. Average Current Rated |
N/A 0.7 A |
Max. Peak Current Rated |
N/A 2.8 A |
Protection Functions |
N/A
Over load protection When a load exceeding rated torque is applied to motor for more than about 5 sec, Stop motor and outputs "L" from "ALARM" in case of power supply for more than 1 min. |
Operation Temperature |
N/A 0~40ºC (no condensation) continuous duty. The motor flange surface temp. must be 80ºC Max. (Ambient temperature 40ºC without heat sink) |
Motor Dielectric Strength |
N/A Withstand for 1 min. under AC500V 50Hz (Between case and coil) |
Motor Insulation Resistance |
N/A 10 MO MIN. (Between case and coil by DC500V tester) |
Number of Poles |
N/A 10 |
Rated Power |
N/A 6 W |