Print Back
Elinco's VH series BLDC motors are an ideal choice for application that requires high reliability, high efficiency, and high power to volume ratio. They are capable of providing a large amount of torque over different speed ranges. The VH series motors are internally commutated motors designed to run from direct current source.
Unit of Measure

Specifications

Series

VH Inner Rotor

Motor Frame Size

60 x 95 mm

Number of Poles

4

Rated Voltage

150 V

Rated Torque

500 mN·m

Rated Speed

14000 rpm

Rotor Inertia

500 g·cm²

Insulation Class

Class B/Class F

Rated Torque

0.5 N·m

Rated Power

750 W

Peak Torque

1.5 N·m

Line to Line Inductance

16 mH

Winding Type

Star

Hall Effect Electrical Angle

120 º

Radial Play at 450 Gram (g) Load

0.02 mm

End Play at 450 Gram (g) Load

0.08 mm

Maximum Axial Force

45 N

Minimum Insulation Resistance for 500 Volt (V) Direct Current (DC) Voltage

100 MO

Number of Phase

3

Continuous Stall Torque

0.6 N·m

Peak Current

17 A

Torque Constant

95 mN·m/A

Body Length

95 mm

Maximum Radial Force at 10 Millimeter (mm) from The Flange

115 N

Line to Line Resistance at 20 Degree Celsius (ºC) Temperature

2 O

Back Electromotive Force (EMF) Constant

7 Vrms/Krpm

Direct Current (DC) Dielectric Strength Voltage for One Minute

500 V

Lead Number

1 2 3 4 5 6 7 8

Color for Lead Number 1

Red

Color for Lead Number 2

Blue

Color for Lead Number 3

Green

Color for Lead Number 4

White

Color for Lead Number 5

Black

Color for Lead Number 6

Yellow

Color for Lead Number 7

Red

Color for Lead Number 8

Black

Lead Gauge for Lead Number 1

American Wire Gauge (AWG) 26

Lead Gauge for Lead Number 2

American Wire Gauge (AWG) 26

Lead Gauge for Lead Number 3

American Wire Gauge (AWG) 26

Lead Gauge for Lead Number 4

American Wire Gauge (AWG) 26

Lead Gauge for Lead Number 5

American Wire Gauge (AWG) 26

Lead Gauge for Lead Number 6

American Wire Gauge (AWG) 18 - 22

Lead Gauge for Lead Number 7

American Wire Gauge (AWG) 18 - 22

Lead Gauge for Lead Number 8

American Wire Gauge (AWG) 18 - 22

Electric Function for Lead Number 1

Voltage Collector Collector (Vcc) (Hall Positive)

Electric Function for Lead Number 2

Hall U

Electric Function for Lead Number 3

Hall V

Electric Function for Lead Number 4

Hall W

Electric Function for Lead Number 5 (Hall Negative)

GND (Hall Negative)

Electric Function for Lead Number 6

Phase U

Electric Function for Lead Number 7

Phase V

Electric Function for Lead Number 8

Phase W

Voltage for Lead Number 1

+5 to +24

Dimensions


VH60S95750-150

Customize

N/A Custom Designs