Japanese Products Corp.
120 Fiske St., Fairfield, CT 06825-5524 US
Phone:203.334.7537 • Fax:203.334.7792
E-Mail: info@e-jpc.com Web site: www.e-jpc.com
All Categories > Fans and Blowers > Silent Fans > Item # D0925C12B6AZ-00  


Item # D0925C12B6AZ-00, Gentle Typhoon™ DC Blower

( Quantity Discount Available )

  • Dimensions: 92 x 25 mm
  • Great air flow rate & long life.
  • Dual speed models are available.
  • Sensor installed models are also offered.




 Specifications 

Type

D0925C Series Brushless DC Fans 92X25

Product Type

Brushless DC Fan

Series

Silent Fans

Noise

35 dB

Rated Speed

3750 r/min

Dimensions

92 x 25 mm

Voltage

12 V

Max Airflow

59 cfm
1.66
m³/min

Max Static Pressure

48 Pa
0.19
inH2O

Operating Voltage

10.2 - 13.2 V

Current Rating

200 mA

Current Starting

650 mA

Operating Temperature

-20 ~ +70 ºC

Weight

100 g

Material

Bearing : Both Side Shielded Ball Bearing
Propeller : SPS synthetic resins

Venturi : SPS Synthetic Resins

Motor

Brushless DC Motor, Protection type : Current shut off by detecting lock state, automatically reset

Qty/Box

70

Carton Size

45 x 38 x 29 cm

Qty/Pallet

840

Standard Pallet Size

790 x 930 x 1020 cm

Box/Pallet

12

Note

  • Figures in the table are average measured values. Please request the product delivery specification when preparing a purchase specification
  • The characteristics are the values at rated voltage, and normal temperature and humidity
  • the only venturi shape available for these products is ribbed flange.
  • This fan is specially designed for long life. At rated voltage and in continuous operation the expected life is 60,000 hours at 60ºC.

Warning

  • Please do not exceed the specifications noted in this catalog, otherwise there is a chance of electric shock, injury, or other damage.
  • Please do not insert your fingers or any other object into the fan's interior, otherwise there is a chance of electric shock, injury, or fire.
  • Any modifications made to this fan are beyond the limits of our guarantee. Japan Servo cannot take responsibility for any customer modifications.
  • Please ensure that a thorough evaluation has been done before using this fan in medical equipment or other devices related to human lives.
  • Please ensure that a thorough evaluation has been done before using this fan in applications that have a serious effect on the public.